Cold Flow Static Nozzle Thrust Stands

Cold Flow Static Nozzle Thrust Stands

Cold Flow Static Thrust Stands
Nozzle Thrust Performance
State of the Art Facility
Flow Visualizations
Air Flow Calibrations
Air Flow Calibrations
Cold Flow Static Nozzle Thrust Stands

Channel 7/8/12 Cold Flow Static Nozzle Test Stands

Channels 7/12 - Typically used to evaluate single, or dual stream plus core vent exhaust system performance at static conditions. Exhaust system models are mounted on a direct connect balance. A three component force balance measures thrust, normal force, and pitching moment. An ASME flow meter determines the mass flow delivered to the facility control volume and the incoming momentum needed for the force balance equation.   

Channel 8 - Typically used to evaluate single or multiple stream exhaust system performance at static conditions. Exhaust system models are mounted on a direct connect 3 or 6 component balance. An ASME flow meter determines the mass flow delivered to the test article. A test chamber and vacuum system can be configured for high NPR simulation.

  • Modular Test Stands (customizable)
  • NPR up to 1000 (CH 8 - dependent on throat areas of the test article)
  • Three or Six Component Balances
  • Metered Flow Measurements (up to 40 pounds per seconds)
  • Pressure and Temperature Measurements
  • High Speed Data Systems
  • FreeJet for High Speed Probe Calibrations
  • Exhaust to Atmosphere or Vacuum
  • High Altitude Simulation (Test Cabins Available)

David Myren - Calspan ASE - Nozzle with Pressure Sensative Paint Flow Vis - Post Processed.gif

Find out how we can
support your innovations